"Gas-freeing without ship's power: planning tank work on a dead ship"

Most tank cleaning plans assume the ship's machinery is running: inert gas plant, cleaning pumps, heaters, fans. On a laid-up, idle or dead ship, some or all of that isn't available. Tank work can still be done, but the plan has to provide what the ship can't.
What changes without ship's power
- No or limited inert gas supply
- No ship's cleaning pumps or heaters
- Fixed ventilation fans may not run
- Lighting and communication limited
- Emergency systems may be reduced
What has to be brought in
Ventilation. Portable fans (air- or water-driven, or suitably rated electric fans) sized for the tank volume and number of tanks.
Power. A temporary generator, placed and connected safely, if electric equipment is used.
Washing. Portable pumps and machines if washing is required, with water supply and heating if needed.
Monitoring. Portable gas detectors for oxygen, hydrocarbons, H2S and other toxic gases, calibrated and in the hands of competent people.
Lighting. Intrinsically safe lights for tank entry.
Safety controls
- Hazard assessment and permit system, as on any tank job
- Atmosphere testing before and during entry, at several levels
- Control of ignition sources, especially with portable power on deck
- Rescue arrangements and equipment ready
- Clear communication between deck, tank and anyone controlling power
See the DPP to CPP changeover guide for tank entry principles.
Planning tips
- Survey the ship first to see what systems actually work.
- Plan ventilation capacity for the whole job, not one tank.
- Allow extra time: gas-freeing without ship's systems is slower.
- Coordinate with the owner or manager on any temporary systems and approvals.
How Cleanship helps
We plan tank work on idle and dead ships with our own portable equipment and riding teams, from our bases at Fujairah and in India. See our DPP and CPP tank cleaning service, demucking, or contact us.
Sources & further reading
Frequently asked questions
Can tanks be gas-freed without ship's power?
Yes, with portable fans, temporary power if needed, portable monitoring and a plan that replaces the ship's systems.
What equipment is needed for gas-freeing a dead ship?
Portable fans, possibly a generator, portable gas detectors, intrinsically safe lighting, and portable pumps and machines if washing is needed.
Does gas-freeing take longer on a dead ship?
Usually, because portable ventilation and equipment set-up take longer than using the ship's fixed systems.
What safety risks are greater on a dead ship?
Reduced emergency systems, ignition sources from temporary power and limited communication, all of which the plan must control.
- gas freeing dead ship
- tank cleaning without power
- portable gas freeing fans
- cold ship tank cleaning
- gas freeing tanker
Related articles
- Tank cleaning"Converting CPP tanks to wall wash standard: when it's needed and what it takes"When charterers ask for wall wash standard on product tankers, what extra preparation it needs beyond a normal clean product standard, and how to plan the time and effort.
- Tank cleaning"Portable machines and high-pressure washing when fixed machines aren't enough"When portable tank cleaning machines and high-pressure washing are needed on a tanker changeover, how they are deployed, and the safety and coating precautions that come with them.
- Tank cleaning"Shadow areas: getting tank cleaning machines to reach everything"What shadow areas are in tanker cargo tanks, why fixed cleaning machines miss them, how to identify them from the shadow diagram, and how to clean them before inspection.
- Tank cleaning"Coated vs uncoated cargo tanks: how the changeover plan changes"How epoxy-coated, other coated and uncoated (bare steel) cargo tanks behave during a DPP to CPP changeover, and how the cleaning plan, time and risk change with each.