By Capt. Neeraj Bharti, Founder, Master Mariner · Published · 2 min read
Author of Bulk Shipping: Risk, Cost & Control (P&P Academy, 2026)
"Why wall wash tests fail: chlorides, hydrocarbons and permanganate time"

A failed wall wash test is frustrating because the tank usually looks clean. The test is detecting something the eye can't see. Each test result points to a different likely cause, and fixing the cause is quicker than re-washing everything and hoping.
How a wall wash test works (briefly)
A small amount of test solvent or water is run down selected areas of the tank wall and collected. The sample is then tested for the parameters in the instructions. Typical ones include chlorides, hydrocarbons, colour and, for some cargoes, permanganate time.
Chlorides high
Likely cause: seawater residue. Tanks were rinsed with seawater and not given enough fresh water rinse, or seawater got in later (through lines, leaks or ballast).
Fix: thorough fresh water rinse of affected tanks, then drain and dry. Check lines and valves for seawater ingress.
Hydrocarbons present
Likely cause: residue of the previous cargo, often in shadow areas, on coils, on damaged coating, or carried back from lines.
Fix: target cleaning of the areas sampled, then flush lines. Check coating condition. See shadow areas.
Permanganate time short
Permanganate time (PTT) tests are used for some sensitive cargoes to detect oxidisable impurities. A short time points to contamination, often from previous cargo traces, cleaning chemicals not fully rinsed, or other organic residue.
Fix: identify the source (previous cargo, chemicals, coating), clean and rinse thoroughly, ventilate and re-test.
Colour or other parameters
Point to residue or contamination that needs tracing to tanks, lines, pumps or coating.
Avoiding failures
- Know the tests and limits before cleaning. See converting to wall wash standard.
- Rinse chemicals completely. See tank cleaning chemicals.
- Fresh water rinse where chlorides are tested.
- Dry and ventilate properly.
- Pre-test on board before the inspector arrives.
How Cleanship helps
We prepare tanks to wall wash standard and trace failed results back to the cause, from our bases at Fujairah and in India. See our DPP and CPP tank cleaning service or contact us.
Sources & further reading
Frequently asked questions
Why do tanks fail wall wash tests for chlorides?
Usually seawater residue from inadequate fresh water rinsing or later seawater ingress through lines, leaks or ballast.
What causes hydrocarbons in a wall wash test?
Residue of the previous cargo, often in shadow areas, on coils or damaged coating, or carried back from lines.
What is permanganate time?
A test used for some sensitive cargoes to detect oxidisable impurities. A short permanganate time indicates contamination.
Should tanks be pre-tested before the wall wash inspection?
Yes. Pre-testing on board helps find and fix problems before the independent inspection.
- wall wash test failed
- chloride wall wash
- hydrocarbon wall wash test
- permanganate time test
- wall wash test causes
Related articles
- Tank cleaning"Visually clean or water white? Agreeing the cleanliness standard before inspection"What common tank cleanliness standards mean in practice, why the standard must be agreed before cleaning starts, and how to avoid disputes at the inspection.
- Tank cleaning"Gas-freeing without ship's power: planning tank work on a dead ship"How to plan gas-freeing and tank cleaning on a tanker with limited or no power, including portable fans, power supply, inert gas, atmosphere monitoring and safety controls.
- Tank cleaning"Converting CPP tanks to wall wash standard: when it's needed and what it takes"When charterers ask for wall wash standard on product tankers, what extra preparation it needs beyond a normal clean product standard, and how to plan the time and effort.
- Tank cleaning"Portable machines and high-pressure washing when fixed machines aren't enough"When portable tank cleaning machines and high-pressure washing are needed on a tanker changeover, how they are deployed, and the safety and coating precautions that come with them.