Skip to content

By , Founder, Master Mariner · Published · 2 min read

Author of Bulk Shipping: Risk, Cost & Control (P&P Academy, 2026)

"Why wall wash tests fail: chlorides, hydrocarbons and permanganate time"

Product tanker cargo tank walls
Product tanker cargo tank walls

A failed wall wash test is frustrating because the tank usually looks clean. The test is detecting something the eye can't see. Each test result points to a different likely cause, and fixing the cause is quicker than re-washing everything and hoping.

How a wall wash test works (briefly)

A small amount of test solvent or water is run down selected areas of the tank wall and collected. The sample is then tested for the parameters in the instructions. Typical ones include chlorides, hydrocarbons, colour and, for some cargoes, permanganate time.

Chlorides high

Likely cause: seawater residue. Tanks were rinsed with seawater and not given enough fresh water rinse, or seawater got in later (through lines, leaks or ballast).

Fix: thorough fresh water rinse of affected tanks, then drain and dry. Check lines and valves for seawater ingress.

Hydrocarbons present

Likely cause: residue of the previous cargo, often in shadow areas, on coils, on damaged coating, or carried back from lines.

Fix: target cleaning of the areas sampled, then flush lines. Check coating condition. See shadow areas.

Permanganate time short

Permanganate time (PTT) tests are used for some sensitive cargoes to detect oxidisable impurities. A short time points to contamination, often from previous cargo traces, cleaning chemicals not fully rinsed, or other organic residue.

Fix: identify the source (previous cargo, chemicals, coating), clean and rinse thoroughly, ventilate and re-test.

Colour or other parameters

Point to residue or contamination that needs tracing to tanks, lines, pumps or coating.

Avoiding failures

  1. Know the tests and limits before cleaning. See converting to wall wash standard.
  2. Rinse chemicals completely. See tank cleaning chemicals.
  3. Fresh water rinse where chlorides are tested.
  4. Dry and ventilate properly.
  5. Pre-test on board before the inspector arrives.

How Cleanship helps

We prepare tanks to wall wash standard and trace failed results back to the cause, from our bases at Fujairah and in India. See our DPP and CPP tank cleaning service or contact us.

Sources & further reading

Frequently asked questions

Why do tanks fail wall wash tests for chlorides?

Usually seawater residue from inadequate fresh water rinsing or later seawater ingress through lines, leaks or ballast.

What causes hydrocarbons in a wall wash test?

Residue of the previous cargo, often in shadow areas, on coils or damaged coating, or carried back from lines.

What is permanganate time?

A test used for some sensitive cargoes to detect oxidisable impurities. A short permanganate time indicates contamination.

Should tanks be pre-tested before the wall wash inspection?

Yes. Pre-testing on board helps find and fix problems before the independent inspection.

  • wall wash test failed
  • chloride wall wash
  • hydrocarbon wall wash test
  • permanganate time test
  • wall wash test causes
Get in touch

Ready when you are.

Tell us the vessel, the port and the window. You get a scope, a crew size and an honest duration — usually the same working day.